Skip navigation
  1. Go back to Catalog

Battery charger & jump starter DOCTOR CHARGE 50 6/12/24V 45A 807598

Index: 807598

Battery charger & jump starter DOCTOR CHARGE 50, charging voltage: 6/12/24 V, starting current: 70A, charging current: 45A, power supply: 230V, battery type: AGM/EFB/GEL/Li/MF/PbCa/WET

Description

 

DOCTOR CHARGE 50 6/12/24V is a multifunctional electronic charger with POWER STREAM technology for comprehensive servicing of WET lead-acid, GEL, Lithium, AGM with fibreglass mat (MF maintenance-free spiral, for Start-Stop systems) batteries and supporting activities in service centres and car showrooms.  DOCTOR CHARGE is a multifunctional device designed for: automatic charging and maintenance with PULSE-TRONIC technology, testing the battery, starting current and alternator, assisting vehicle start-up (model.50), desulphation and battery regeneration. It is also a source of stable voltage during battery replacement, programming, diagnostic activities and during work in car showrooms.

Innovative POWER STREAM technology guarantees up to 50% better results compared to a traditional charger through a more efficient and fully controlled charging process. More efficient power transfer and shorter charging time result in increased battery efficiency and longer lifespan.

The 8-step charging process ensures optimal battery charging conditions: EXAMINATION (checking the battery charge status, verifying the set voltage), DESULPHATION (detection and regeneration of sulphated batteries), ANALYSIS (battery condition analysis allows detection of a faulty battery), MAIN CHARGING (maximum current to achieve 80% charge), FINAL CHARGING (decreasing current to achieve 100% charge), CHECK (operation check, verification if the battery maintains charge), MAINTENANCE (charging with constant voltage), PULSE (pulse regeneration).

Control panel functions

CHARGING

- CHARGE AUTO – automatic charging: automatic current selection during charging and maintenance depending on battery capacity

- CHARGE MAN – charging, manual settings: individual settings for battery type, charging current or capacity (Ah)

- MAINTAIN – maintenance charging: pulse charging through PULSE TRONIC technology

- MONITOR – charging status control: continuous monitoring of charging phases

- BOOST – fast charging and automatic transition to maintenance phase when charging is complete

- COLD – cold battery charging function: optimises charging at very low temperatures (low temperatures can adversely affect the chemical structure of battery components)

- SILENT – silent operation function: quiet charging with reduced current to avoid disturbing silence with fan operation

REGENERATION

- DESULFATION – desulphation: pulse regeneration process of sulphated batteries allows removal of sulphates from lead plates and results in recovery of battery capacity

- EQUALIZATION – equalisation: specific function for periodic maintenance to restore optimal status of WET or AGM batteries by mixing elements

POWER SUPPLY

- DIAGNOSTIC – diagnostics, programming: silent stabilised power source for vehicle installations during diagnostics and programming, protects the battery from voltage drop and discharge

- FINE SET – precise power supply voltage setting: advanced diagnostic function allowing precise change of the charger's output voltage

- MEMORY SAVER – voltage retention, no data loss: power source to maintain vehicle electronic systems during battery replacement, prevents data loss

- SHOW ROOM – operation in car showrooms: power source during work in car showrooms, protects batteries from discharge

- LOCK MODE – parameter change lock: control panel lock prevents accidental change of device output parameters.

TEST

- VOLT – battery voltage and charge status test

- START – battery starting current test (CCA)

- ALTERNATOR – alternator operation test

START-UP ASSISTANCE (mod.50)

- Fully safe vehicle start-up assistance 6/12V

MEMORY – retention of last settings: each time the charger is turned on, it automatically sets the last remembered parameters (helpful for repeated use and power supply interruptions)

PROTECTION – full safety and protection against reverse polarity, terminal short circuit, overload and charging of a faulty battery

ECONOMY – minimal power consumption, automatic shutdown after a period of inactivity

LOW VOLTAGE – charging batteries with very low initial voltage to min.2V

CALIBRATION – calibration of output cables depending on their length guarantees optimal parameters delivered to the battery during charging and to the vehicle during diagnostics.

Possibility of wall mounting using a bracket (available separately) and extending output cables to 6 and 10 metres (available separately).

 

 

 

Technical specification
Name
Battery charger & jump starter
Model
DOCTOR CHARGE 50
Charging voltage

12.0V

24.0V

6.0V
Charging current
45.0A
Charging current 6V
40.0A
Charging current 12V
40.0A
Charging current 24V
20.0A
Rated charging current

20.0A

40.0A
Starting current
70.0A
Rated CCA
70.0A
Power
600.0W
Battery type

AGM

EFB

GEL

Li

MF

PbCa

WET
Power supply
230.0V
Charged battery capacity at 6V
10-600Ah
Charged battery capacity at 12V
10-600Ah
Charged battery capacity at 24V
10-600Ah
Protection against

battery overcharge

overheating

reversed polarization

short circuit

sparking
Protection level
IP20
Replacements

Inquire about the price

[email protected]
Phone Number
Battery charger & jump starter DOCTOR CHARGE 50 6/12/24V 45A 807598 CMS.INTERCARS_MD.SEO_META_TITLE_CATALOG_PRODUCT_SUFFIX