Other diagnostic devices CG-1U-P
Index: CG-1U-P
Diagnostic device
The CG-1U gas detector is a portable device designed for inspecting and detecting leaks in gas installations containing natural gas, city gas, or a propane-butane mixture. The device is equipped with a 10-point gas detection indicator and manual sensitivity adjustment in 3 ranges. The detector features optical, acoustic (increasing), or vibrational gas detection signals.
Technical description of the device
- Sensor used: semiconductor,
- Type of measurement: continuous diffusion,
- Detectable gases: methane, propane, isobutane,
- Detectable vapours: gasoline, alcohol, solvents,
- Gas detection signal: optical (10-point LED indicator), acoustic, or vibrational,
- Measurement circuit fault control and signal: optical and acoustic,
- Power supply: 2 LR6 AA batteries (1.5V) – alkaline batteries recommended, 2 LR6 AA rechargeable batteries (1.2V) – charged in the device or external charger,
- Continuous operation time: ~11h (Ni-MH 2300mAh rechargeable); ~6h (alkaline batteries),
- Battery status control (rechargeable battery charge status) with battery replacement signal (rechargeable battery charging): optical,
- Measuring probe: extendable telescope: length ~120cm, plastic sensor tip ø 21mm, in version P - flexible conduit,
- Dimensions (length/width/height): 141mm/68mm/18mm,
- Weight: ~240g.
Description
The CG-1U gas detector is a portable device designed for inspecting and detecting leaks in gas installations containing natural gas, city gas, or a propane-butane mixture. The device is equipped with a 10-point gas detection indicator and manual sensitivity adjustment in 3 ranges. The detector features optical, acoustic (increasing), or vibrational gas detection signals.
Technical description of the device
- Sensor used: semiconductor,
- Type of measurement: continuous diffusion,
- Detectable gases: methane, propane, isobutane,
- Detectable vapours: gasoline, alcohol, solvents,
- Gas detection signal: optical (10-point LED indicator), acoustic, or vibrational,
- Measurement circuit fault control and signal: optical and acoustic,
- Power supply: 2 LR6 AA batteries (1.5V) – alkaline batteries recommended, 2 LR6 AA rechargeable batteries (1.2V) – charged in the device or external charger,
- Continuous operation time: ~11h (Ni-MH 2300mAh rechargeable); ~6h (alkaline batteries),
- Battery status control (rechargeable battery charge status) with battery replacement signal (rechargeable battery charging): optical,
- Measuring probe: extendable telescope: length ~120cm, plastic sensor tip ø 21mm, in version P - flexible conduit,
- Dimensions (length/width/height): 141mm/68mm/18mm,
- Weight: ~240g.
Technical specification
Name
Diagnostic device