Battery charger & jump starter DOCTOR CHARGE 130 12/24V 140A 807848

Index: 807848

Battery charger & jump starter DOCTOR CHARGE 130, charging voltage: 12/24 V, starting current: 180A, charging current: 140A, power supply: 230V, battery type: AGM/EFB/GEL/Li/MF/PbCa/WET

Description
DOCTOR CHARGE 130 PFC is a multifunctional electronic charger with POWER STREAM technology for comprehensive servicing of WET, GEL, AGM, Lithium batteries and supporting operations in service centres and car showrooms. Power supply 230V.

DOCTOR CHARGE 130 12/16/24V is a multifunctional electronic charger with POWER STREAM technology for comprehensive servicing of WET lead-acid, GEL, Lithium, AGM with fibreglass mat (MF maintenance-free, spiral, for Start-Stop systems) batteries and supporting operations in service centres and car showrooms. DOCTOR CHARGE is a multifunctional device designed for: automatic charging and maintenance with PULSE-TRONIC technology, testing the battery, starting current and alternator, assisting vehicle starting, desulphation and regeneration of batteries. It is also a source of stable voltage during battery replacement, programming, diagnostic activities and during work in car showrooms.

Innovative POWER STREAM technology guarantees up to 50% better results compared to a traditional charger through a more efficient and fully controlled charging process. More efficient power transfer and shorter charging time result in increased battery performance and longer lifespan.

The device allows safe charging of 16 V lithium batteries in electric vehicles. It also features precise voltage stabilisation (14–16 V, every 0.1 V) under load up to 120 A. Ideal for diagnostics, ECU programming and work in exhibition conditions.

The 8-step charging process ensures optimal battery charging conditions: EXAMINATION (checking the battery charge status, verifying the set voltage), DESULPHATION (detection and regeneration of sulphated batteries), ANALYSIS (battery condition analysis allows detection of a faulty battery), MAIN CHARGING (maximum current to achieve 80% charge), FINAL CHARGING (decreasing current to achieve 100% charge), CHECKING (checking operation, verifying if the battery maintains charge), MAINTENANCE (charging with constant voltage), PULSE (pulse regeneration).

Control panel functions
CHARGING
- CHARGE AUTO – automatic charging: automatic current selection during charging and maintenance depending on battery capacity
- CHARGE MAN – charging, manual settings: individual settings for battery type, charging current or capacity (Ah)
- MANTAIN – maintenance charging: pulse charging through PULSE TRONIC technology
- MONITOR – charge status monitoring: continuous monitoring of charging phases
- BOOST – fast charging and automatic transition to maintenance phase when charging is complete
- COLD – cold battery charging function: optimises charging at very low temperatures (low temperatures can adversely affect the chemical structure of battery components)
- SILENT – silent operation function: quiet charging with reduced current to avoid disturbing silence with fan operation

REGENERATION
- DESULFATION – desulphation: pulse regeneration process of sulphated batteries allows removal of sulphates from lead plates and results in recovery of battery capacity
- EQUALIZATION – equalisation: specific function for periodic maintenance to restore optimal status of WET or AGM batteries by mixing elements

POWER SUPPLY
- DIAGNOSTIC – diagnostics, programming: silent stabilised power source for vehicle installations during diagnostics and programming, protects the battery from voltage drop and discharge
- FINE SET – precise power supply voltage setting: advanced diagnostic function allowing precise change of the charger's output voltage
- MEMORY SAVER – voltage retention, no data loss: power source to maintain vehicle electronic systems during battery replacement, prevents data loss
- SHOW ROOM – operation in car showrooms: power source during work in car showrooms, protects batteries from discharge
- LOCK MODE – parameter change lock: control panel lock prevents accidental change of the device's output parameters.

TEST 
- VOLT – battery voltage and charge status test
- START – battery starting current test (CCA)
- ALTERNATOR – alternator operation test

START ASSISTANCE
- fully safe start assistance for 12/24V vehicles

MEMORY – retention of last settings: each time the charger is turned on, it automatically sets the last remembered parameters (helpful for repeated use and during power outages)
PROTECTION – full safety and protection against reverse polarity, short circuit of clamps, overload and charging of a faulty battery
ECONOMY – minimal power consumption, automatic shutdown after a period of inactivity
LOW VOLTAGE – charging batteries with very low initial voltage within 2V
CALIBRATION – calibration of output cables depending on their length guarantees optimal parameters delivered to the battery during charging and to the vehicle during diagnostics.

Technical specification
Name
Battery charger & jump starter
Model
DOCTOR CHARGE 130
Charging voltage

12.0V

24.0V
Charging current
140.0A
Charging current 12V
120.0A
Charging current 24V
60.0A
Rated charging current

120.0A

60.0A
Starting current
180.0A
Rated CCA
120.0A
Power

1800.0W

2000.0W
Battery type

AGM

EFB

GEL

Li

MF

PbCa

WET
Power supply
230.0V
Charged battery capacity at 12V
20-1200Ah
Charged battery capacity at 24V
20-1200Ah
Protection against

battery overcharge

overheating

reversed polarization

short circuit

sparking
Protection level
IP20